产品类
Calentadormdicomóvil/be
Articulo编号:sbN-100
esben-100mdiodador del Bebe/be
偶数dro | |
马尔卡: | 爱游戏彩票app下载 |
MOQ: | 一号 |
斜率 : | 卡通打包 |
Navede: | 广州 |
铁波德埃斯佩拉: | 3-7天 |
Personalización: | 有 |
德克里普西翁
医疗移动婴儿/婴儿保暖器YSBN-100
1.Microprocessor based servo controlled temperature system.
2.The microprocessor-controlled unit allows for three settings:
pre-warm, manual or automatic.
3.Alarm functions for safety includes:
Power failure, temperature deviation,
Temperature sensor failure , over temperature.
4.APGAR timer to record therapy time
5.Convenient X-ray cassette under infant bed
5.Heater head can be adjusted + 90º horizontally
6.Tilt angle of infant bed is adjustable
7.Observe light angle is adjustable
8.Transparent protector folded
9.Adopts anti-explosion micro crystal quartz infrared radiation tube for its
radiation source, the heating is quick and life-span is long
10.Alarms are audible and visual
11.A second thermal cut-out function for more safety
12.Skin temperature sensor failure protect function avoid over temperature
13.Temperature deviation can be amended in front panel directly
14.Low pressure aspirator, oxygen supply system and LED phototherapy unit
15.Electric height adjusted suit for operation
技术数据
1.Power supply : 110/220V 60/50Hz
2. Power input: ≤1200VA
3. Operating condition
An ambient Temperature:18°C-30°C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity <0.3m/s
4. Temperature control: 32°C~38°C
5.Temperature control accuracy: ≤0.5°C
6.Mattress temperature uniformity : <2°C
7.Skin temperature sensor accuracy: + 0.3°C
8.Warm-up time: ≤30min
9. Infant Bed tilt angle:+ 10°
10.APGAR timer range: ≤24h
11.Heater head horizontal: ±90°
12.Mattress size: 67CM X 54CM
13.Distance from heater to mattress:90CM
14.Height adjustable range:0-20CM
15.LED phototherapy light: 2pcs X 8W
Transport and storage
Environment Temperature:-40°C~ +55°C
Environment Relative Humidity: ≤95%
Atmospheric Pressure: 500~1060hPa
包数 :
Each unit is packed one case
Size:135CMX 85CM X 98CM Gross weight: ≤170KG
1.Microprocessor based servo controlled temperature system.
2.The microprocessor-controlled unit allows for three settings:
pre-warm, manual or automatic.
3.Alarm functions for safety includes:
Power failure, temperature deviation,
Temperature sensor failure , over temperature.
4.APGAR timer to record therapy time
5.Convenient X-ray cassette under infant bed
5.Heater head can be adjusted + 90º horizontally
6.Tilt angle of infant bed is adjustable
7.Observe light angle is adjustable
8.Transparent protector folded
9.Adopts anti-explosion micro crystal quartz infrared radiation tube for its
radiation source, the heating is quick and life-span is long
10.Alarms are audible and visual
11.A second thermal cut-out function for more safety
12.Skin temperature sensor failure protect function avoid over temperature
13.Temperature deviation can be amended in front panel directly
14.Low pressure aspirator, oxygen supply system and LED phototherapy unit
15.Electric height adjusted suit for operation
技术数据
1.Power supply : 110/220V 60/50Hz
2. Power input: ≤1200VA
3. Operating condition
An ambient Temperature:18°C-30°C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity <0.3m/s
4. Temperature control: 32°C~38°C
5.Temperature control accuracy: ≤0.5°C
6.Mattress temperature uniformity : <2°C
7.Skin temperature sensor accuracy: + 0.3°C
8.Warm-up time: ≤30min
9. Infant Bed tilt angle:+ 10°
10.APGAR timer range: ≤24h
11.Heater head horizontal: ±90°
12.Mattress size: 67CM X 54CM
13.Distance from heater to mattress:90CM
14.Height adjustable range:0-20CM
15.LED phototherapy light: 2pcs X 8W
Transport and storage
Environment Temperature:-40°C~ +55°C
Environment Relative Humidity: ≤95%
Atmospheric Pressure: 500~1060hPa
包数 :
Each unit is packed one case
Size:135CMX 85CM X 98CM Gross weight: ≤170KG
或同似